Pages

    phypa.org / Guides

    When an EEG event duration is missing, what does the record actually establish?

    · · Worked example and worksheet

    Two rows in an EEG event table have the same duration entry, n/a. In one case the export log says the stop marker was omitted. In the other case, the available notes say nothing. Both cells can carry the same missing-value marker. They leave the next researcher with different leads.

    1. Read the field definition before choosing a value

    The Brain Imaging Data Structure (BIDS) defines event duration in seconds. An event modeled as an impulse can have duration 0. An unavailable duration can be n/a. These entries mean different things even if a spreadsheet invites you to format the whole column as numbers. See the BIDS events specification and its rules for missing and non-applicable values in tabular files.

    Use a separate working ledger to record the event reference, the literal value, the evidence available for it and the next check. The downloadable CSV is a teaching ledger. An actual BIDS events file has its own required columns, units and tab-separated format.

    2. Trace each row to a stated piece of evidence

    All four records below are invented. They describe metadata for one example run and contain no signal measurements.

    • ev-01: The two marker times in the example export are 3.00 and 3.60 seconds. Their difference gives a duration of 0.60 seconds.
    • ev-02: The example protocol defines a cue marker as an impulse. Enter 0. The zero expresses the modeling convention. It says nothing about how long a physical device took to present a cue.
    • ev-03: The example export log explicitly reports omission of this event’s stop marker. Keep n/a and record which log gives that explanation. Nothing in the export establishes when the event ended.
    • ev-04: The duration field is unavailable and the delivered notes contain no explanation. Keep n/a and write “cause unresolved.” Borrowing ev-03’s explanation would create a second claim from a single log entry.

    3. Check what zero-filling would change

    Of four events, two have numeric durations. The mean of those two recorded values, including the deliberately instantaneous cue, is (0.60 + 0) / 2 = 0.30 seconds. Replacing both missing values with zero produces (0.60 + 0 + 0 + 0) / 4 = 0.15 seconds. The second calculation gives the undocumented events a duration and changes the denominator.

    This arithmetic checks the handling of the example, not whether an average across these event types would answer a research question. For a report, write which types were included and give the observed and missing counts. The benchmark notes guide provides space to record the dataset version and processing decisions alongside a result.

    4. Leave a question someone can resolve

    For ev-03, ask whether an earlier export retains the omitted marker. For ev-04, identify the source log or export specification that could establish what happened. If neither can be found, retain the unresolved status. If a later file supplies an offset, keep the original reference and identify the new file and the revision in which the value changed.

    Download the four-record missing-data ledger and try sorting by the evidence column. The two missing rows should stay recognizable as separate cases. If those records later feed a benchmark, the participant split audit gives a separate check on how records were assigned to evaluation folds.

    This new guide is independently maintained and is not issued by the former organization or authors. Related editorial guides are part of the same maintained collection.